ReviewReview DateStatusComments
Building03/04/2013RejectedThis review is conducted according to the 2009 Virginia Residential Code. More information is needed to obtain the building permit. Section numbers are listed for your convenience. This URL address gives you reading rights for the 2009 VA Residential Code provided the ICC web site is available. http://www.ecodes.biz/ecodes_support/Free_Resources/Virginia2009/09Residential/09Residential_main.html 1. DES requires a 1" water service & corresponding meter for more than three (3) baths. 2. Please show how the existing interior stairs satisfy - R311.7.1 for stair width, R311.7.2 for headroom, R311.7.4.1 for riser height, R311.7.4.2 for tread depth, R311.7.4.3 for profile, R311.7.5 for landings, R311.7.7.1 for handrail height, R311.7.7.3 for han
Building03/08/2013NOTATIONComplete review done. No building rejection items at this time. Must review again after zoning approval. Please contact ISD reviewer when zoning approval has been obtained to process permit.
Building03/13/2013NOTATIONComplete review done. No building rejection items at this time. Must review again after zoning approval. Please contact ISD reviewer when zoning approval has been obtained to process permit.
Building03/14/2013Approved as NotedA two-story addition with basement attached to the rear of existing two and a half story dwelling with alteration being proposed to interior. An areaway and covered stoop is proposed to be attached to the east side of the building and existing covered porch is proposed to be screened in with screens only. Patios are proposed on the rear of the dwelling. New window well on front of building is being proposed.
Building04/19/2013Approved as NotedRoof Trusses Shop Drawings as designed signed, and sealed By Mr. Frank R. Lassiter Professional Engineer in the commonwealth of Virginia Lic # 034728 dated April 11, 2013.
DES: Parks Recreation/Comm. Re03/15/2013Approved 
DES:Engineering03/15/2013Approved 
DES:Engineering06/03/2013ApprovedRECOUNTED THE DFU'S IN THE BUILDING PERMIIT. DISCOVERED THAT THE BATHROOM IN THE BASEMENT WAS AN EXISTING POWDER ROOM TURNDED TO A FULL BATH. FOR THE ADDITION OF A SHOWER, APPLICANT MUST PAY FOR 2 EXTRA DRAINAGE FIXTURE UNITS. A PLUMBING PERMIT MAY NOW BE AMENDED TO ADD THE SHOWER TO THE SCOPE OF WORK.
DES:Water/Sewer Engineering03/15/2013Approved 
DES:Water/Sewer Engineering03/15/2013RejectedTHE AREA HAVE TO HAVE A WRITTEN NOTE TO STAKE OUT THE AREA. THE ADDITION IS BETWEEN 2000- 2500 SEQ.FT.
DES:Water/Sewer Engineering06/03/2013ApprovedRECOUNTED THE DFU'S IN THE BUILDING PERMIIT. DISCOVERED THAT THE BATHROOM IN THE BASEMENT WAS AN EXISTING POWDER ROOM TURNDED TO A FULL BATH. FOR THE ADDITION OF A SHOWER, APPLICANT MUST PAY FOR 2 EXTRA DRAINAGE FIXTURE UNITS. A PLUMBING PERMIT MAY NOW BE AMENDED TO ADD THE SHOWER TO THE SCOPE OF WORK.
DES:WSESite Plan Review03/15/2013Approved 
Zoning03/04/2013RejectedBAR SINK LETTER REQUIRED FOR ADDITIONAL SINKS IN MUD ROOM AND BASEMENT. 2 STORY REAR ADDITION AND FINISH BASEMENT. ENCLOSE EXISTING NONCONFORMING PORCH. 8' RIGHT SETBACK (STAIRS 5' RIGHT SETBACK), 16' TO REAR DETACHED GARAGE, 35' TO REAR LOT LINE. HOUSE ORIGINALLY BUILT IN 1933 - NONCONFORMING SIDE SETBACKS. ADDITION TO BE IN CONFORMITY. AC UNIT LEFT SIDE SET BACK 11.5'. WINDOW WELL AT FRONT OF DWELLING SET BACK 38' FROM FRONT. HEIGHT OF ADDITION LOWER THAN HEIGHT OF EXISTING (EXISTING IS 2.5 STORIES). LOT COVERAGE OK. WALL CHECK REQUIRED.
Zoning03/11/2013NOTATIONThis plan was distributed to Aundrae Lee 703-228-3228
Zoning03/14/2013ApprovedA two-story addition with basement attached to the rear of existing two and a half story dwelling with alteration being proposed to interior. An areaway and covered stoop is proposed to be attached to the east side of the building and existing covered porch is proposed to be screened in with screens only. Patios are proposed on the rear of the dwelling. Three AC units are being proposed for the west side of the building. New window well on front of building is being proposed. Please see comments below: 1. 1. Bar sink approval has been obtained for bar sink in basement media room. Please see ZADM13166. 2. AC units are not approved with this permit and require a separate permit. The location of the AC units shown in set is allowe