Permit #B1801397
Address4150 CAMPBELL AVE
TypeCTBO
StatusFINALED
Permit HolderI-CE-NY JIE C. LI
OwnerUDR DELANCEY AT SHIRLINGTON LLC
Applied Date05/23/2018
Approved Date07/30/2018
Date Issued08/02/2018
DescriptionTEANT IMPROVMENT PLAN ICE CREAM TAKE OUT

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewBuilding
Review Date05/31/2018
StatusApproved
Comments
Sheet A-101 CODE PLAN: Occupant load calculations are incorrect. Please use the right load factors based on the function of each space in the tenant. For example, dining tables should be done at 15 SF/Occp, kitchen should be done at 200 SF/Occp, restrooms and circulation areas should be done at 100 SF/Occp, if queuing is anticipated it should be done at 5 SF/Occp. Please revise and show on the plan all different space functions and related occupant load.
  



  
 