Search for Permits

Use the search below to get details on plan review activities and review comments on your plans. This information is updated Monday through Friday at 12:30 p.m. and 5:30 p.m.

Information returned on this page is valid through 6/27/2022. Incorporating the new permitting system data into this website is in progress. For current data requests, please contact PermitTechSupport@arlingtonva.us

 
Permit #B1803426
Address4201 WILSON BLVD
TypeCTBO
StatusFINALED
Permit HolderGR RESTORATION PAINTING INC.
OwnerJAMESTOWN PREMIER STAFFORD I LLC
Applied Date12/14/2018
Approved Date04/12/2019
Date Issued04/16/2019
DescriptionINTERIOR ALTERATION OF AN EXISTING SPACE FOR NEW TENANT, THAT INCLUDES NON-STRUCTURAL PARTITIONS, DOORS, FIXTURES AND RELATED. UNIT 140 - COREPOWER YOGA

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewEnergy
Review Date02/04/2019
StatusApproved
Comments
Section C405.2.1.1 of the 2015 VECC requires that occupant sensor controls function in a manner that automatically turns off lights within 30 minutes of all occupants leaving the space. Sheet E101 lighting key note 3 states that the hallway occupancy sensor will dim lighting to 50% when the hallway is not occupied. This does not meet code, as the code requires that the occupancy sensor control shut off the non-emergency lighting.
In the resubmission revise the design to comply with section C405.2.1.1 of the 2015 VECC.
****02/04/2019**** comment partially addressed. Lighting key note 3 does states "turn lighting within 30 minutes of all occupants leaving space." This is not the correct sequence of operation. The correct sequence is, "turn lighting OFF within 30 minutes of all occupants leaving the space."
"lighting will be turned off within 30 minutes of all occupants leaving the space" it states "lighting will be turned."
  



  
 