Permit #B1901467
Address3217 10TH ST N
TypeCTBO
StatusFINALED
Permit HolderJULIANO DESIGN BUILD
OwnerGOLDEN HELENE B TR ET AL
Applied Date05/28/2019
Approved Date08/07/2019
Date Issued08/20/2019
Description*** INTERIOR ALTERATIONS OF 1ST. FLOOR FOR NEWBATHROOMS. ADD SMALL FOOD PREP AREA TO 2ND. FLOOR. ***

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewBuilding
Review Date05/30/2019
StatusApproved
Comments
Manually operated surface or flush bolts are not permitted on means of egress doors (Section 1008.1.9.4). Where egress doors are used in pairs, automatic flush bolts may be used on the inactive leaf provided no surface mounted hardware is mounted on that door leaf (Section 1008.1.9.3(3)). Please see proposed deadbolts on new bathroom doors, proposed locking system on doors should function as an automatic flush bolts, when the door lever is operated door should unlock automatically if the doors functions as such then please provide a note on hardware schedule indicating so. Currently hardware schedule only indicates deadbolts (Hardware sets no 1 and 2)
  



  
 