Search for Permits

Use the search below to get details on plan review activities and review comments on your plans. This information is updated Monday through Friday at 12:30 p.m. and 5:30 p.m.

Information returned on this page is valid through 6/27/2022. Incorporating the new permitting system data into this website is in progress. For current data requests, please contact PermitTechSupport@arlingtonva.us

 
Permit #B2100260
Address2805 CLARENDON BLVD
TypeCTBO
StatusFINALED
Permit HolderPOTOMAC CONSTRUCTION SERVICES INC
OwnerCLARENDON REGENCY IV LLC % REGENCY CENTERS LP
Applied Date02/03/2021
Approved Date03/30/2021
Date Issued03/30/2021
DescriptionTENANT BUILD-OUT OF A NEW TATTE BAKERY WITHIN EXISTING CORE AND SHELL SPACE. THE WORK WILL CONSIST OF NEW INTERIOR PARTITIONS, FINISHES AND NEW MEP THROUGHOUT TO CONNECT TO BUILDING SERVICES. SPECIAL INSPECTIONS REQUIRED

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewEnergy
Review Date02/17/2021
StatusApproved
Comments
Sheet E-703 includes an interior lighting COMcheck. The COMcheck appears to be incorrect in the following ways. First, there are exemptions claimed for several fixtures of the K and D type. Section C405.4 of the 2015 VECC does not allow for these fixtures to be exempt from the calculation. These emergency lighting fixtures are not exempt from the calculation because they are also used for general lighting. Fixture M is missing from the COMcheck calculation but present in the lighting schedule. The input power for fixtures F and G are not coordinated between the COMcheck calculation and the lighting schedule. In the resubmission include all required fixtures and use the correct wattage in the COMcheck calculation.
  



  
 
Search Permits By:   Address
Permit Number
Date