Permit #B2200196
Address4710 LANGSTON BLVD
TypeCTBO
StatusAPPLIED
Permit HolderCONTRACTOR TBD
OwnerJAMES WILSON CONSTITUTIONAL SOCIETY LLC
Applied Date02/01/2022
Approved Date 
Date Issued 
DescriptionNEW TENANT BUILD OUT FOR COFFEE CAFE, INTERIOR DEMO, NEW MECHANICAL, PLUMBING, ELECTRICAL, COFFEE EQUIPMENT, FIXTURES, AND FURNITURE. CHANGE OF USE FROM B TO A-2.

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewBuilding
Review Date02/09/2022
StatusRejected
Comments
Sheet A106 DOOR AND WALL TYPES: Refer to Section 1010.1.1. Min 32" clear door opening required measured door face to jamb. Both restroom doors (type 1)scheduled as 30" wide. In addition, BOH door (type 2) is a double door with 2 - 1'-6" leaves. One leaf in a pair is required to meet the 32" clearance requirement.
  



  
 