Permit #B2201067
Address2618 S JOYCE ST
TypeRNEW
StatusAPPLIED
Permit HolderTROUTMAN & CO
OwnerCOMBS STEVEN C & CELINE T COMBS
Applied Date05/23/2022
Approved Date 
Date Issued 
DescriptionCOMBS STEVEN C & CELINE T COMBS

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewBuilding
Review Date06/07/2022
StatusRejected
Comments
06/07/2022 Under the prescriptive compliance approach, slab edge insulation must be R-10 minimum at the slab perimeter, with an overall length (horizontal and/or vertical) of 2 feet.
Ref. 2018 IRC with Virginia Amendments Table (N1102.1.1).
The slab edge need be insulated only when the slab (or some portion of its perimeter) is within 12" of grade;
(Ref. Section R1102.2.9.
When the slab itself is heated (e.g., via embedded hot water pipes), slab edge insulation must be increased to R15 where it is at or near grade.
  



  
 