Permit Comments Details
 
Permit #B1902272
Address5183 LEE HWY
TypeComm Int Alt
StatusFINALED
Permit HolderARLINGTON RIDGE CONSTRUCTION GROUP INC
OwnerGARDEN CITY SHOPPING CENTER L P % ALLAN BERMAN
Applied Date08/15/2019
Approved Date12/02/2019
Date Issued12/03/2019
DescriptionINTERIOR ALTERATION TO AN EXISTING SPACE FOR A NEW TENANT TO INCLUDE A NEW RESTROOM, NEW ELECTRICAL WORK, MODIFICATIONS TO THE EXISTING HVAC SYSTEM, AND INSTALLATION OF AN ABOVE GROUND MODULAR SPA.

 

 
ReviewEnergy
Review Date10/23/2019
StatusApproved
Comments
Sheet A-001 has been revised to indicate that a new entrance door is part of the scope of the permit. This door must meet the minimum air infiltration, U-factor, and Solar Heat Gain Coefficient (SHGC) requirements of the 2012 VECC. Tables C402.3 and C402.5.2 of the 2012 VECC require a maximum allowable air infiltration rate of 0.20 CFM/SF, a maximum allowable U-factor of 0.77 and a maximum allowable SHGC of 0.40.
In the resubmission state the maximum allowable air infiltration rate, U-factor and SHGC on the drawings in the door schedule.