Review | Building |
Review Date | 05/12/2022 |
Status | Rejected |
Comments |
Sheet X - AccessibilityComplianceForm2012: New design complying with chapter 11 VCC and A117.1 2009, are not considered accessible upgrades. An accessible upgrade is taking an existing condition that does not comply, and altering it so that it does comply with accessibility requirements of the VCC. If the building is considered fully accessible meeting the accessibility requirements in the VCC, then Box 1 may be checked. If there are still elements of this facility that need to be upgraded, and the alterations within this permit will have the building fully compliant, then box 3 may be checked and those upgrades must be shown on the plans. If upgrades are still required but would exceed more than 20% of the proposed alterations, then Box 4 can be checked, and must complete upgrades up to 20% of the alteration cost, list those upgrades here and show upgrades on the plan under this permit. |
|