Permit #B1901467
Address3217 10TH ST N
TypeCTBO
StatusFINALED
Permit HolderJULIANO DESIGN BUILD
OwnerGOLDEN HELENE B TR ET AL
Applied Date05/28/2019
Approved Date08/07/2019
Date Issued08/20/2019
Description*** INTERIOR ALTERATIONS OF 1ST. FLOOR FOR NEWBATHROOMS. ADD SMALL FOOD PREP AREA TO 2ND. FLOOR. ***

View Event Log.      View Status.    View Required Plan Review       View Printer Version.

Review   Review       Date Status   Comments   
Building08/06/2019Approved Sheet A-001 Architectural Code Analysis & Site Plan: Revised fixture count to 6 male and 6 female toilets.
Building07/23/2019Approved Occupant load shall be determined in accordance with Sec. 1004 and Table 1004.1.2. The occupant loads of rooms and spaces are based on the way the room or space is used, not necessarily on Occupancy Classification of the building, floor, or tenant. Be sure that functions of all rooms and spaces are identified on the plans. Please include overall occupant load of the space, number of bathrooms  more...
Building06/04/2019Approved Unfortunately i will not be available via phone call due to personal reasons, best way to get in touch is via email in case designer needs clarifications email: ikaraaslan@arlingtonva.us
Building05/30/2019Approved Manually operated surface or flush bolts are not permitted on means of egress doors (Section 1008.1.9.4). Where egress doors are used in pairs, automatic flush bolts may be used on the inactive leaf provided no surface mounted hardware is mounted on that door leaf (Section 1008.1.9.3(3)). Please see proposed deadbolts on new bathroom doors, proposed locking system on doors should function as an  more...
Building05/30/2019Approved The "Accessibility Compliance Form" is MISSING. The designer must complete the form and attach the original to the County plan set and a copy to each additional set of plans.
DES:Water/Sewer Engineering08/07/2019Eplan Review Note COMMERCIAL INT ALT. 55 NEW DFU'S. APPROVED
EPlan Review08/07/2019Approved --N/A--
Plumbing 05/31/2019Approved 5-31-19 Please provide Menu, For possible Grease Interceptor requirements. Please supply ADA Compliance Form .
Plumbing 05/31/2019Approved 5-31-19 Please verify Occp Count, Refer to Bldg Review comments.
Zoning 07/28/2019Approved Please provide the setback from the food trailers to the center line of the streets. The required setback must be no less than 50 feet.
Zoning 06/07/2019Approved Zoning Ordinance requirement for Outdoor cafes. Article 12.9.15 Outdoor cafés Outdoor cafes may be allowed only as accessory to otherwise allowed restaurants, subject to the following requirements: A. Outside of public rights-of-way or easements for public use Outdoor cafes are allowed, subject to approval by the Zoning Administrator, when they are located outside of public rights-of-way or  more...
Zoning 06/07/2019Approved Permit for interior alterations to existing commercial building to create public bathrooms and food preparation area. Permit includes outdoor seating area as well as food trailers. Permit is rejected until all comments are addressed.
Zoning 06/07/2019Approved The permit mention the Beer Lot restaurant as the main use for this permit, however there are no interior seating area associated with this restaurant. An outdoor cafe seating area is an accessory use to a main restaurant use and can only be approved once a certificate of occupancy is issued for the main use. In addition, per the Zoning Ordinance Article 12. the number of Outdoor seats cannot  more...