Permit #B2200650
Address2910 COLUMBIA PIKE
TypeCTBO
StatusAPPLIED
Permit HolderCONTRACTOR TBD
OwnerARLINGTON FREE CLINIC INC
Applied Date03/30/2022
Approved Date 
Date Issued 
DescriptionNEW OWNER, PAINTING, FLOORING AND NEW VENTILATION ONLY NO GAS AND PLUMBING CHANGE, EXISTING LAYOUT TO REMAIN TENANT : Nightbird Restaurant & Lounge

View Event Log.      View Status.    View Required Plan Review       View Printer Version.

Review   Review       Date Status   Comments   
Building07/01/2022Rejected Sheet A005_EquipmentSchedule: The area of the mezzanine containing the divider walls and lounge furniture is a dead end exceeding 20' for an A use. The condition is existing, however adding the walls and lounge furniture makes the condition worse as there is no line of sight and area to return in the direction from which you have come. Please show a condition compliant with VCC 1020.4
Building06/22/2022Rejected Sheet A004_ProposedMezzanine: Please provide an area analysis for the mezzanine demonstrating the additional floor area still qualifies as a mezzanine per VCC 505
Building06/22/2022Rejected Sheet A004_ProposedMezzanine: Stated 36" high handrail should be a 42" high guardrail complying with 1015 VCC. Please include construction details for the rail.
Building06/22/2022Rejected Sheet CS000_Coversheet: Please include area occupant load for both levels with seating and standing area calculations.
Building06/22/2022Rejected Please update all MEP plan sheets showing the new layout of the mezzanine which includes the added floor area.
Building06/22/2022Rejected Please provide exit lighting plan for mezzanine.
Building06/22/2022Rejected Sheet A004_ProposedMezzanine: This is a type II A building. The new mezzanine floor must be non combustible protected per VCC table 601
Building06/22/2022Rejected Sheet A004_ProposedMezzanine: Show 5% accessible seating at bar,tables and banquette per VCC 1108.2.9.1
Building06/22/2022Rejected Sheet A004_ProposedMezzanine: Provide door and hardware schedule for door at new smoking room.
Building06/08/2022Rejected Plans returned to submitter to rename the files with descriptive names. Please give the files names that will help the reviewers find what they are looking for. A descriptive file name might be "A3 - PROPOSED FIRST FLOOR PLAN" for example. Name the files as shown in your Drawing Index on CS - COVER SHEET. ************* 6/8/22 ************ Comment not addressed.
DES:Water/Sewer Engineering06/07/2022Approved CTBO INT ALT USING EXISTING FIXTURES
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Please confirm area of smoke room which is 189 SF.
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Smoking room ventilation must be in accordance with VMC 2015 table 403.3.1.1 and must under negative pressure.
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Recirculation or air from smoking room is prohibited.
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Provide outside air calculations for above referenced project for each area (VMC 2015 or 2018 table 403.3.1.1).
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Provide mechanical first floor plan, demolition and new work.
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Show location of convection oven on floor plan and it's ventilation system including cut sheet.
Mechanical06/30/2022Rejected Sheet M002_NewExhaustedFanplan: Show mechanical lay-out for mezzanine floor plan
Public Health Division06/06/2022Approved Sheet A4: Confirm that smoking will not be permitted to occur outside of the smoking room.
Public Health Division06/06/2022Approved Sheet A4: Show a space with a dedicated sink within the establishment for cleaning any equipment associated with smoking.