Building07/07/2022Rejected 07/07/2022 Not Addressed. ______________________________________________________________________________________________________________ 06/07/2022 1. The rear walls of the garage distance from the property line. 2. Please show how the wall satisfies the requirements of Table R302.1 for fire resistance rated walls within five feet (5') of the property line and for eave projections of the  more...
Building07/07/2022Rejected 07/07/2022 Please note that any engineered method design must include a complete wind load analysis such as described in Section 1609 in the 2018 Virginia Construction Code. Please include complete design calculations for all elements. We should be able to follow the load path through every element of the design to the foundation. (Ref. 2018 VRC/IRC R301.2.1, R602.10) Provide  more...
Building07/07/2022Rejected 07/07/2022 Not Provided. 06/07/2022 Please provide your civil plans in order for ISD to be able to perform a complete review.
Building07/07/2022Rejected 07/07/2022 Please Submit a structural cross section including the water proofing and damp proofing requirements - R406.1 and how the external footing drain is not impaired by its supporting structure - R405.1. ______________________________________________________________________________________________________________ 06/07/2022 17. A DES planter is proposed for this project, as per showing  more...
Building06/07/2022Rejected 06/07/2022 Under the prescriptive compliance approach, slab edge insulation must be R-10 minimum at the slab perimeter, with an overall length (horizontal and/or vertical) of 2 feet. Ref. 2018 IRC with Virginia Amendments Table (N1102.1.1). The slab edge need be insulated only when the slab (or some portion of its perimeter) is within 12" of grade; (Ref. Section R1102.2.9. When the slab  more...
Building06/07/2022Rejected 06/07/2022 Please revise the bedroom at the basement accessed trough the laundry room.
Building06/07/2022Rejected 06/07/2022 Please note that the garage slab appears to be structurally deficient. Please provide calculations for the submitted design. (Ref. 2018 VRC/IRC R301.5)
Building06/07/2022Rejected 06/07/2022 14. Fire Extinguisher having a rating of “2-A: 10-B: C” or an approved equivalent type of fire extinguisher shall be installed in the kitchen area per Section R-330.1
Building06/07/2022Rejected 06/07/2022 Detail the section for example the hurricane ties, the sill plates, anchors to the foundation, ledger boards, exterior stairs stringers, stairs pad or footers. extra...
Building06/07/2022Rejected 06/07/2022 • Please provide the dimensions for the bathroom, including the required fixture clearances per VRC figure R307.1 and section P2705.1. show on the plan to have the required 21" of clearance in front of the toilet, the 15" of clearance from the centerline of the sink to any side wall, 15" from the center line of the toilet to any side wall or vanity. per VRC figure R307.1 and section  more...
Building06/07/2022Rejected 06/07/2022 15. Identify the hazardous locations needing safety glass as per R308.4 section.
Building06/07/2022Rejected 06/07/2022 Rejection are not limited to the above rejections, submission was not a complete set to receive a complete rejections.
Building06/07/2022Rejected 06/07/2022 NOTE: Please do not quote Code sections on the drawings to show compliance for any of the plan review comments listed above. Your submitted drawings were not complete and the revisions/responses for the above code comments may require additional information and generate additional code comments. Please contact me if you have any questions on the requested information or need  more...
Building06/07/2022Rejected 06/07/2022 Please be aware that "When submitting revisions, the areas of change shall be "bubbled" on the new sheets If the changes are made clear it will greatly reduce the time for the second review. Provide a written response to each of the following review comments when the revision is submitted. Best Regards, Shinaze Saad Saleh Phone: (703) 228. 3856 E-mail:  more...
Building06/07/2022Rejected This review is conducted 06/07/2022 according to the 2015 Virginia Residential Code. More information is needed to obtain the building permit. Section numbers are listed for your convenience. This web site address will give reading rights for the 2015 VA Residential Code provided the ICC web site is available.   more...
Building06/07/2022Rejected 06/07/2022 In order to be able to analyze whether proposed construction complies with the Virginia uniform statewide building code, construction plans must meet minimum level of completeness. Submitted plans must contain sufficient information for plan reviewers to be able to review the proposed construction work. When submitted plans do not meet a minimum level of completeness, ISD cannot provide  more...
Building06/07/2022Rejected This review is conducted 06/07/2022 according to the 2015 Virginia Residential Code. More information is needed to obtain the building permit. Section numbers are listed for your convenience. This web site address will give reading rights for the 2015 VA Residential Code provided the ICC web site is available.   more...
Building06/07/2022Rejected 06/07/2022 In order to be able to analyze whether proposed construction complies with the Virginia uniform statewide building code, construction plans must meet minimum level of completeness. Submitted plans must contain sufficient information for plan reviewers to be able to review the proposed construction work. When submitted plans do not meet a minimum level of completeness, ISD cannot provide  more...
Building06/07/2022Rejected 06/07/2022 Please provide your civil plans in order for ISD to be able to perform a complete review.
Building06/07/2022Rejected 06/07/2022 17. A DES planter is proposed for this project, as per showing its location on the basement floor plan and in elevation, and section, you must detail its supporting structure. Submit a structural cross section including the water proofing and damp proofing requirements - R406.1 and how the external footing drain is not impaired by its supporting structure - R405.1. As well must  more...